http://myexs.ru/wp-content/themes/multiflex-4-10/img/header.gif
http://myexs.ru/wp-content/themes/multiflex-4-10/img/bg30.jpg

Gravity-Balancing Leg Orthosis and Its Performance Evaluation

Дата: Декабрь 6th, 2006 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 6092
  • Название документа: Gravity-Balancing Leg Orthosis and Its Performance Evaluation
  • Номер (DOI, IBSN, Патент): Не заполнено
  • Изобретатель/автор: Wei-Li Hsu, Vijaya Krishnamoorthy, Sunil K. Agrawal, Sai K. Banala, Katherine Rudolph, John Scholz, Abbas Fattah
  • Правопреемник/учебное заведение: Не заполнено
  • Дата публикации документа: 2006-12-06
  • Страна опубликовавшая документ: Не заполнено
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: IEEE TRANSACTIONS ON ROBOTICS,
  • Вложения: Да
  • Аналитик: Глаголева Елена

In this paper, we propose a device to assist persons with hemiparesis to walk by reducing or eliminating the effects of gravity. The design of the device inclu-des the following features:1) it is passive, i.e., it does not include motors or actuators, but is only composed of links and springs; 2) it is safe and has a simple patient–machine interface to accommodate variability in geometry and inertia of the subjects. A number of methods have been proposed in the litera-ture to gravity-balance a machine. Here, we use a hybrid method to achieve gravity balancing of a human leg over its range of motion. In the hybrid method, a mechanism is used to first locate the center of mass of the human limb and the orthosis. Springs are then added so that the system is gravity-balanced in every configuration. For a quantitative evaluation of the performance of the device, electromyographic (EMG) data of the key muscles, involved in the motion of the leg, were collected and analyzed. Further experi-ments involving leg-raising and walking tasks were performed, where data from encoders and force-torque sensors were used to compute joint torques. These experiments were performed on five healthy subjects and a stroke patient. The results showed that the EMG activity from the rectus femoris and hamstring muscles with the device was reduced by 75%, during static hip and knee flexion, respectively. For leg-raising tasks, the average torque for static positioning was reduced by 66.8% at the hip joint and 47.3% at the knee joint; however, if we include the transient portion of the leg-raising task, the average torque at the hip was reduced by 61.3%, and at the knee was increased by 2.7% at the knee joints. In the walking experi-ment, there was a positive impact on the range of movement at the hip and knee joints, especially for the stroke patient: the range of movement increased by 45% at the hip joint and by 85% at the knee joint.We believe that this orthosis can be potentially used to design rehabilitation protocols for pa-tients with stroke. Index Terms—Gait rehabilitation, gravity balancing, inverse dynamics, passive ortho-sis, rehabili-tation robotics.

Категория: Научные статьи | Нет комментариев »

Комментарии

Добавить комментарий

Ваш e-mail не будет опубликован. Обязательные поля помечены *


Статистика

Категорий: 179
Статей всего: 2,003
По типу:
 Видео: 36
 Выдержка с форума: 1
 Контактные данные: 12
 Научная статья: 1388
 Не заполнено: 5
 Новостная статья: 317
 Обзор технологии: 42
 Патент: 219
 Тех.подробности: 34
 Тип: 1
Комментариев: 6,672
Изображений: 3,005
Подробней...

ТОР 10 аналитиков

    Глаголева Елена - 591
    Дмитрий Соловьев - 459
    Helix - 218
    Ридна Украина))) - 85
    Наталья Черкасова - 81
    max-orduan - 29
    Елена Токай - 15
    Роман Михайлов - 9
    Мансур Жигануров - 4
    Дуванова Татьяна - 3

Календарь

  • Декабрь 2006
    Пн Вт Ср Чт Пт Сб Вс
    « Ноя   Янв »
     123
    45678910
    11121314151617
    18192021222324
    25262728293031
  • Авторизация

    Ошибка в тексте?

    Выдели её мышкой!

    И нажми Ctrl+Enter