http://myexs.ru/wp-content/themes/multiflex-4-10/img/header.gif
http://myexs.ru/wp-content/themes/multiflex-4-10/img/bg30.jpg

Surface EMG pattern recognition for real-time control of a wrist exoskeleton

Дата: Декабрь 31st, 2010 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 6247
  • Название документа: Surface EMG pattern recognition for real-time control of a wrist exoskeleton
  • Номер (DOI, IBSN, Патент): Не заполнено
  • Изобретатель/автор: Zeeshan O Khokhar, Zhen G Xiao, Carlo Menon
  • Правопреемник/учебное заведение: Simon Fraser University
  • Дата публикации документа: 2010-12-31
  • Страна опубликовавшая документ: Канада
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: Khokhar et al. BioMedical Engineering OnLine
  • Вложения: Да
  • Аналитик: Глаголева Елена

Background: Surface electromyography (sEMG) signals have been used in numerous studies for the classification of hand gestures and movements and successfully implemented in the position control of different prosthetic hands for amputees. sEMG could also po-tentially be used for controlling wearable devices which could assist persons with reduced muscle mass, such as those suffering from sarcopenia. While using sEMG for position control, estimation of the intended torque of the user could also provide sufficient information for an effective force control of the hand prosthesis or assistive device. This paper presents the use of pattern re-cognition to estimate the torque applied by a human wrist and its real-time implementation to control a novel two degree of freedom wrist exoskeleton prototype (WEP), which was specifically developed for this work.
Methods: Both sEMG data from four muscles of the forearm and wrist torque were collected from eight volunteers by using a custom-made testing rig. The features that were extracted from the sEMG signals included root mean square (rms) EMG amplitude, autoregres-sive (AR) model coefficients and waveform length. Support Vector Machines (SVM) was employed to extract classes of different force intensity from the sEMG signals. After assessing the off-line performance of the used classification technique, the WEP was used to validate in real-time the proposed classification scheme.
Results: The data gathered from the volunteers were divided into two sets, one with nineteen classes and the second with thirteen classes. Each set of data was further divided into training and testing data. It was observed that the average testing accuracy in the case of nineteen classes was about 88% whereas the average accuracy in the case of thirteen classes reached about 96%. Clas-sification and control algorithm implemented in the WEP was executed in less than 125 ms.
Conclusions: The results of this study showed that classification of EMG signals by separating different levels of torque is possi-ble for wrist motion and the use of only four EMG channels is suitable. The study also showed that SVM classification technique is suitable for real-time classification of sEMG signals and can be effectively implemented for controlling an exoskeleton device for assisting the wrist.

Категория: Научные статьи | Нет комментариев »

Комментарии

Добавить комментарий

Ваш e-mail не будет опубликован. Обязательные поля помечены *


Статистика

Категорий: 179
Статей всего: 2,003
По типу:
 Видео: 36
 Выдержка с форума: 1
 Контактные данные: 12
 Научная статья: 1388
 Не заполнено: 5
 Новостная статья: 317
 Обзор технологии: 42
 Патент: 219
 Тех.подробности: 34
 Тип: 1
Комментариев: 6,236
Изображений: 3,005
Подробней...

ТОР 10 аналитиков

    Глаголева Елена - 591
    Дмитрий Соловьев - 459
    Helix - 218
    Ридна Украина))) - 85
    Наталья Черкасова - 81
    max-orduan - 29
    Елена Токай - 15
    Роман Михайлов - 9
    Мансур Жигануров - 4
    Дуванова Татьяна - 3

Календарь

  • Декабрь 2010
    Пн Вт Ср Чт Пт Сб Вс
    « Ноя   Янв »
     12345
    6789101112
    13141516171819
    20212223242526
    2728293031  
  • Авторизация

    Ошибка в тексте?

    Выдели её мышкой!

    И нажми Ctrl+Enter