http://myexs.ru/wp-content/themes/multiflex-4-10/img/header.gif
http://myexs.ru/wp-content/themes/multiflex-4-10/img/bg30.jpg

Robust EMG sensing system based on data fusion for myoelectric control of a robotic arm

Дата: Февраль 25th, 2009 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 6244
  • Название документа: Robust EMG sensing system based on data fusion for myoelectric control of a robotic arm
  • Номер (DOI, IBSN, Патент): 10.1186/1475-925X-8-5
  • Изобретатель/автор: Natalia M López, Fernando di Sciascio, Carlos M Soria, Max E Valentinuzzi
  • Правопреемник/учебное заведение: Не заполнено
  • Дата публикации документа: 2009-02-25
  • Страна опубликовавшая документ: Аргентина
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: BioMedical Engineering OnLine
  • Вложения: Да
  • Аналитик: Глаголева Елена

Background: Myoelectric control of a robotic manipulator may be disturbed by failures due to disconnected electrodes, interface impedance changes caused by movements, problems in the recording channel and other various noise sources. To correct these prob-lems, this paper presents two fusing techniques, Variance Weighted Average (VWA) and Decentralized Kalman Filter (DKF), both based on the myoelectric signal variance as selecting criterion.
Methods: Tested in five volunteers, a redundant arrangement was obtained with two pairs of electrodes for each recording channel. The myoelectric signals were electronically amplified, filtered and digitalized, while the processing, fusion algorithms and control were implemented in a personal computer under MATLAB® environment and in a Digital Signal Processor (DSP). The experiments used an industrial robotic manipulator BOSCH SR-800, type SCARA, with four degrees of freedom; however, only the first joint was used to move the end effector to a desired position, the latter obtained as proportional to the EMG amplitude.
Results: Several trials, including disconnecting and reconnecting one electrode and disturbing the signal with synthetic noise, were performed to test the fusion techniques. The results given by VWA and DKF were transformed into joint coordinates and used as com-mand signals to the robotic arm. Even though the resultant signal was not exact, the failure was ignored and the joint reference signal never exceeded the workspace limits. Conclusion: The fault robustness and safety characteristics of a myoelectric controlled
manipulator system were substantially improved. The proposed scheme prevents potential risks for the operator, the equipment and the environment. Both algorithms showed efficient behavior. This outline could be applied to myoelectric control of prosthesis, or assistive manipulators to better assure the system functionality when electrode faults or noisy environment are present.

Категория: Научные статьи | Нет комментариев »

Комментарии

Добавить комментарий

Ваш e-mail не будет опубликован. Обязательные поля помечены *


Статистика

Категорий: 179
Статей всего: 2,003
По типу:
 Видео: 36
 Выдержка с форума: 1
 Контактные данные: 12
 Научная статья: 1388
 Не заполнено: 5
 Новостная статья: 317
 Обзор технологии: 42
 Патент: 219
 Тех.подробности: 34
 Тип: 1
Комментариев: 6,672
Изображений: 3,005
Подробней...

ТОР 10 аналитиков

    Глаголева Елена - 591
    Дмитрий Соловьев - 459
    Helix - 218
    Ридна Украина))) - 85
    Наталья Черкасова - 81
    max-orduan - 29
    Елена Токай - 15
    Роман Михайлов - 9
    Мансур Жигануров - 4
    Дуванова Татьяна - 3

Календарь

  • Февраль 2009
    Пн Вт Ср Чт Пт Сб Вс
    « Янв   Мар »
     1
    2345678
    9101112131415
    16171819202122
    232425262728  
  • Авторизация

    Ошибка в тексте?

    Выдели её мышкой!

    И нажми Ctrl+Enter