Архив категории Ищем научные статьи

Efficient Design of a Torque Actuator for Lower Extremity Exoskeleton Based on Muscle Function Analysis

Дата: Август 1st, 2011 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 3597
  • Название документа: Efficient Design of a Torque Actuator for Lower Extremity Exoskeleton Based on Muscle Function Analysis
  • Номер (DOI, IBSN, Патент): 10.4028/www.scientific.net/AMR.328-330.1041
  • Изобретатель/автор: Sahba Safavi, Meghdari, A., Ghafari, A.S.
  • Правопреемник/учебное заведение: Sch. of Mech. Eng., Sharif Univ. of Technol., Tehran
  • Дата публикации документа: 2011-09-01
  • Страна опубликовавшая документ: Иран
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: http://www.scientific.net/AMR.328-330.1041
  • Вложения: Нет
  • Аналитик: Helix

Several lower extremity exoskeletal systems have been developed for augmentation purpose. Common actuators, have important drawbacks such as complexity, and poor torque capacities. The main scope of this research is to propose a series elastic actuator for lower extremity exoskeletal system which was designed based on muscle functional analysis. For this purpose, a biomechanical framework consisting of a musculoskeletal model with ten degrees-of-freedom actuated by eighteen Hill-type musculotendon actuators per leg is utilized to perform the muscle functional analysis for common daily human activities. The simulation study illustrated functional differences between flexor and extensor muscles and the results were utilized for efficient design of the series elastic torque actuator employed in lower extremity exoskeletons.

Категория: Ищем научные статьи | Нет комментариев »


Wilmington Robotic Exoskeleton: A Novel Device to Maintain Arm Improvement in Muscular Disease

Дата: Август 1st, 2011 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 4084
  • Название документа: Wilmington Robotic Exoskeleton: A Novel Device to Maintain Arm Improvement in Muscular Disease
  • Номер (DOI, IBSN, Патент): 10.1097/BPO.0b013e31821f50b5
  • Изобретатель/автор: Sample, W., Rahman, T., M. King, M., Jayakumar, Shanmuga, Henley, J., Haumont, T., Church, C.
  • Правопреемник/учебное заведение: Rockland Rd, Wilmington
  • Дата публикации документа: 2011-08-01
  • Страна опубликовавшая документ: США
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: http://journals.lww.com/pedorthopaedics/Abstract/2011/07000/
  • Вложения: Нет
  • Аналитик: Helix

Background: Upper-extremity movement is limited in individuals with muscular weakness. This paper describes a novel, articulated upper-extremity orthosis, the Wilmington Robotic Exoskeleton (WREX), which helps people overcome this movement deficit.

Methods: This prospective, case-controlled study involved an ambulatory patient with arthrogryposis multiplex congenita and 2 nonambulatory patients with spinal muscular atrophy type II. The WREX uses elastic bands to negate the effects of gravity; it allows a person with neuromuscular weakness to move their arm in 3 dimensions. The WREX can be fixed on a brace for ambulatory patients and on the wheelchair for nonambulatory patients. Assessment was performed through motion analysis (with and without the WREX), clinical examination, and qualitative questionnaire.

Results: Motion analysis showed a marked improvement in upper-extremity function with the WREX. The questionnaire illustrated enhanced functionality with the WREX including self-feeding, fine motor control, and use of a television remote control. Enhanced functionality resulted in improved quality of life by increasing participation in school, raising self-esteem, and increasing social interaction. Two unexpected outcomes were increased security with trunk inclination and amelioration of the effects of contractures.

Conclusions: The WREX provided an increase in functionality and improved the quality of life of the patients. The device has become an integral part of the lives of the 3 patients.

Level of Evidence: Level III in Therapeutic Studies-Investigating the Results of Treatment.

Категория: Ищем научные статьи | Нет комментариев »


Development of a real-time upper limb’s motion tracking exoskeleton device for active rehabilitation using an inertia sensor

Дата: Август 1st, 2011 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 3588
  • Название документа: Development of a real-time upper limb's motion tracking exoskeleton device for active rehabilitation using an inertia sensor
  • Номер (DOI, IBSN, Патент): 10.1109/WCICA.2011.5970708
  • Изобретатель/автор: Zhibin Song, Shuxiang Guo
  • Правопреемник/учебное заведение: Grad. Sch. of Eng., Kagawa Univ., Takamatsu, Japan
  • Дата публикации документа: 2011-08-01
  • Страна опубликовавшая документ: Япония
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: http://ieeexplore.ieee.org/Xplore/login.jsp?url=http%3A%2F%2
  • Вложения: Нет
  • Аналитик: Helix

In this paper, a real-time upper limb’s motion tracking exoskeleton device is proposed and developed, which can be used in active rehabilitation of upper limb for stroke. This device is portable and wearable and is potential to be used in the passive and active training for stroke patients. Passive training has been finished in previous work and in this paper, the preliminary work for active rehabilitation is presented, which is realization of the real-time upper limb’s motion tracking. We use an adaptive weighted average filtering and double close-loop control to realize real-time and stable tracking performance. Experiments have been conducted to prove that it is suitable for active rehabilitation.

Категория: Ищем научные статьи | Нет комментариев »


A novel 3-DOF optical force sensor for wearable robotic arm

Дата: Август 1st, 2011 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 3441
  • Название документа: A novel 3-DOF optical force sensor for wearable robotic arm
  • Номер (DOI, IBSN, Патент): 10.1007/s12541-011-0080-1
  • Изобретатель/автор: Youn-Sung Choi, Sarmad Shams, Dong Su Kim, Chang-soo Han
  • Правопреемник/учебное заведение: Dept. of Mech. Eng., Hanyang Univ., Seoul, South Korea
  • Дата публикации документа: 2011-08-01
  • Страна опубликовавшая документ: Корея
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: http://www.springerlink.com/content/x83087x887802k20/
  • Вложения: Нет
  • Аналитик: Helix

This paper presents a novel 3-DOF optical force sensor for the wearable robotic arm. Precise sensing of human motion is still a challenge. As human motion detection sensors are expected to generate the real time data, with simultaneous measurement of multiple degrees of freedom. The optical sensing is considered to be standard for monitoring the human motion. The optical sensor is consists of high speed camera with integrated DSP (Digital Signal Processor). The DSP use to detect the changes in the sequence of frames to calculate the direction and displacement of its motion in a plane. On the other hand optical sensor eliminates the requirement of being in contact with the subject. Hand is the end-effecter of the arm and can be controlled by a 3-DOF (degree of freedom) shoulder, 2-DOF elbow and 2-DOF wrist joint. In this paper we present a new technique to measure the human’s hand movement in 3 dimensions translation frame. An intelligent computational method for this sensory system to measure the applied force is also developed. The optical force sensor was calibrated and then several experiments were conducted to check the feasibility of sensory system with the wearable robotic arm.

Категория: Ищем научные статьи | Нет комментариев »


The radiation burden from increasingly complex endovascular aortic aneurysm repair

Дата: Июль 31st, 2011 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 4071
  • Название документа: The radiation burden from increasingly complex endovascular aortic aneurysm repair
  • Номер (DOI, IBSN, Патент): 10.1007/s13244-011-0120-5
  • Изобретатель/автор: Michael E. Gaunt, Mathew Mercuri, Claire Cousins, Avnesh S. Thakor, Andrew Winterbottom
  • Правопреемник/учебное заведение: Dept. of Radiology, Addenbrookes Hospital, Univ. of Cambridge, Cambridge, UK
  • Дата публикации документа: 2011-07-31
  • Страна опубликовавшая документ: Великобритания
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: http://www.springerlink.com/content/h0747573177x61x5/
  • Вложения: Нет
  • Аналитик: Helix

Objectives

With increasing experience, endovascular aortic aneurysm repair (EVAR) has been extended to patients with less suitable aorto-iliac anatomy in an attempt to reduce peri-operative mortality. However, more complex EVAR procedures may take longer and can result in higher rates of complications, additional interventional procedures and more frequent radiological imaging, which may offset some of the benefit. This study determined the radiation burden for standard EVAR, as determined by the EVAR-1 trial criteria, and more complex EVAR.

Methods

A total of 123 elective patients aged >60, with aneurysms >5.5 cm who received a bifurcated stent-graft were allocated into a group based on whether or not they fulfilled strict EVAR-1 trial criteria. The mean radiation dose was calculated for each group, together with the additional radiation burden from routine pre- and post-EVAR CT examinations and pre-EVAR iliac artery embolisation.

Results

Patients not meeting the EVAR-1 trial criteria had significantly longer fluoroscopic screening times and higher radiation doses. The radiation burden in all patients was higher following exposure from routine CT examinations and following pre-EVAR iliac artery embolisation.

Conclusion

Whilst the radiation from standard EVAR is acceptable, more complicated and challenging EVARs, accompanied with additional radiological investigations and procedures, can significantly increase the radiation burden.

Категория: Ищем научные статьи | Нет комментариев »