Архив категории Ищем научные статьи
Hand function recovery in chronic stroke with HEXORR robotic training: A case series
- Тип контента: Научная статья
- Номер документа: 1679
- Название документа: Hand function recovery in chronic stroke with HEXORR robotic training: A case series
- Номер (DOI, IBSN, Патент): 10.1109/IEMBS.2010.5626037
- Изобретатель/автор: Schabowsky, C.N., Holley, R.J., Godfrey, S.B.
- Правопреемник/учебное заведение: Catholic Univ. of America, Washington, DC, USA
- Дата публикации документа: 2010-11-11
- Страна опубликовавшая документ: США
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Не заполнено
- Аналитик: Не заполнено
After a stroke, many survivors have impaired motor function. Robotic rehabilitation techniques have emerged to provide a repetitive, activity-based therapy at potentially lower cost than conventional methods. Many patients exhibit intrinsic resistance to hand extension in the form of spasticity and/or hypertonia. We have developed a therapy program using the Hand ExoskeletonRehabilitation Robot (HEXORR) that is capable of compensating for tone to assist patients in opening the paretic hand. The system can move the user’s hand, assist movement, allow free movement, or restrict movement to allow static force production. These options combine with an interactive virtual reality game to enhance user motivation. Four chronic stroke subjects received 18 sessions of robot therapy as well as pre and post evaluation sessions. All subjects showed at least modest gains in active finger range of motion (ROM) measured in the robot, and all but one subject had gains in active thumb ROM. Most of these gains carried over to ROM gains outside of the robot. The clinical measures (Fugl-Meyer, Box-and-Blocks) showed clear improvements in two subjects and mixed results in two subjects. Overall, the robot therapy was well received by subjects and shows promising results. We conclude HEXORR therapy is best suited for patients with mild-moderate tone and at least minimal extension.
Категория: Ищем научные статьи | Нет комментариев »
Development of grip amplified glove using bi-articular mechanism with pneumatic artificial rubber muscle
- Тип контента: Научная статья
- Номер документа: 1673
- Название документа: Development of grip amplified glove using bi-articular mechanism with pneumatic artificial rubber muscle
- Номер (DOI, IBSN, Патент): 10.1109/ROBOT.2010.5509393
- Изобретатель/автор: Tadano, K., Kawashima, K., Kadota, K., Akai, M.
- Правопреемник/учебное заведение: Precision & Intell. Lab., Tokyo Inst. of Technol., Yokohama, Japan
- Дата публикации документа: 2010-07-15
- Страна опубликовавшая документ: Япония
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Не заполнено
- Аналитик: Не заполнено
In this paper, a grip amplified glove using pneumatic artificial rubber muscles (PARMs) which are covered with a exoskeletonstructure is developed. A bi-articular mechanism with a PARM that is suitable for bending finger is realized. The glove has totally 10 DOFs consist of four units. To achieve power-assist motion properly, the PI control, which is based on the pressure value from the balloon sensor, is performed. This sensor makes the applied part free from electricity. To evaluate the validity of glove, the skin surface electromyography (EMG) signals of muscles are measured during grasping. These results demonstrate that the effectiveness of the power amplified glove.
Категория: Ищем научные статьи | Нет комментариев »
Whole-hand kinesthetic feedback and haptic perception in dextrous virtual manipulation
- Тип контента: Научная статья
- Номер документа: 1671
- Название документа: Whole-hand kinesthetic feedback and haptic perception in dextrous virtual manipulation
- Номер (DOI, IBSN, Патент): 10.1109/TSMCA.2003.812600
- Изобретатель/автор: Tzafestas, C.S.
- Правопреемник/учебное заведение: Lab. de Robotique de Paris, France
- Дата публикации документа: 2003-06-20
- Страна опубликовавшая документ: Франция
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Не заполнено
- Аналитик: Не заполнено
One of the key requirements for a Virtual Reality system is the multimodal, real-time interaction between the human operator and a computer simulated and animated environment. This paper investigates problems related particularly to the haptic interaction between the human operator and a virtual environment. The work presented here focuses on two issues: 1) the synthesis of whole-hand kinesthetic feedback, based on the application of forces (torques) on individual phalanges (joints) of the human hand, and 2) the experimental evaluation of this haptic feedback system, in terms of human haptic perception of virtual physical properties (such as the weight of a virtual manipulated object), using psychophysical methods. The proposed kinesthetic feedback methodology is based on the solution of a generalized force distribution problem for the human hand during virtual manipulation tasks. The solution is computationally efficient and has been experimentally implemented using an exoskeleton force-feedback glove. A series of experiments is reported concerning the perception of weight of manipulated virtual objects and the obtained results demonstrate the feasibility of the concept. Issues related to the use of sensory substitution techniques for the application of haptic feedback on the human hand are also discussed.
Категория: Ищем научные статьи | Нет комментариев »
RUPERT closed loop control design
- Тип контента: Научная статья
- Номер документа: 1669
- Название документа: RUPERT closed loop control design
- Номер (DOI, IBSN, Патент): 10.1109/IEMBS.2010.5627647
- Изобретатель/автор: Ruihua Wei, Jiping He, Herman, R., Hang Zhang, Buchanan, S., Balasubramanian, S., Austin, H.
- Правопреемник/учебное заведение: Sch. of Biol. & Health Syst. Eng., Arizona State Univ., Tempe, AZ, USA
- Дата публикации документа: 2010-11-11
- Страна опубликовавшая документ: США
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Не заполнено
- Аналитик: Не заполнено
Robot-assisted rehabilitation is an active area of research in the field of stroke rehabilitation. RUPERT is a wearable roboticexoskeleton powered by pneumatic muscle actuators. In this study, we described the structure of the controllers for the five degrees of freedom currently used by RUPERT. We applied the RUPERT on 6 stroke patients to provide robot-assisted rehabilitation therapy in a clinical study. Statistical χ2 test on the proportion of successfully reaching targets showed that 3 out of the 6 patients demonstrated significant improvement in reaching targets successfully, and the remaining 3 did not show performance improvement or deterioration. We plan to implement the RUPERT in the patient’s house for easier access and more frequent use. More significant performance results are expected.
Категория: Ищем научные статьи | Нет комментариев »
Dynamic simulation and experimental validation of an upper extremity powered orthosis
- Тип контента: Научная статья
- Номер документа: 1663
- Название документа: Dynamic simulation and experimental validation of an upper extremity powered orthosis
- Номер (DOI, IBSN, Патент): 10.1109/AIM.2010.5695915
- Изобретатель/автор: Sample, W., Rahman, T., Agrawal, S.K.
- Правопреемник/учебное заведение: Dept. of Mech. Eng., Univ. of Delaware, Newark, DE, USA
- Дата публикации документа: 2011-01-20
- Страна опубликовавшая документ: США
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Не заполнено
- Аналитик: Не заполнено
The Wilmington Robotic Exoskeleton (WREX) is a passive upper limb orthosis powered by elastic bands, designed to assist children with weakness in their upper limbs. Patient studies with the WREX have determined that an external power source would enhance performance of the system. Two actuation schemes were considered: (i) motors in series with springs at the joints, called `Torsional’ (ii) motors in series with gravity balancing elastic bands, called `In-line’. Dynamic models of these two motor placements were developed. Dynamic simulations, based on representative patient motion data, were performed. We observed that the torsional case with motors in series with springs at the joints required substantially less torque when compared to the in-line case with motors in series with gravity balancing springs. An experimental platform is being developed with this configuration and preliminary results are included.
Категория: Ищем научные статьи | Нет комментариев »
Статистика
Категорий: 179
Статей всего: 2,003
По типу:
Видео: 36
Выдержка с форума: 1
Контактные данные: 12
Научная статья: 1388
Не заполнено: 5
Новостная статья: 317
Обзор технологии: 42
Патент: 219
Тех.подробности: 34
Тип: 1
Комментариев: 6,672
Изображений: 3,005
Подробней...
ТОР 10 аналитиков
-
Глаголева Елена - 591
Дмитрий Соловьев - 459
Helix - 218
Ридна Украина))) - 85
Наталья Черкасова - 81
max-orduan - 29
Елена Токай - 15
Роман Михайлов - 9
Мансур Жигануров - 4
Дуванова Татьяна - 3
Календарь
Пн | Вт | Ср | Чт | Пт | Сб | Вс |
---|---|---|---|---|---|---|
« Ноя | ||||||
1 | 2 | 3 | ||||
4 | 5 | 6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 | 16 | 17 |
18 | 19 | 20 | 21 | 22 | 23 | 24 |
25 | 26 | 27 | 28 | 29 | 30 |
Авторизация
Ошибка в тексте?
Выдели её мышкой!
И нажми Ctrl+Enter