The radiation burden from increasingly complex endovascular aortic aneurysm repair
+ Показать свойства документа
- Тип контента: Научная статья
- Номер документа: 4071
- Название документа: The radiation burden from increasingly complex endovascular aortic aneurysm repair
- Номер (DOI, IBSN, Патент): 10.1007/s13244-011-0120-5
- Изобретатель/автор: Michael E. Gaunt, Mathew Mercuri, Claire Cousins, Avnesh S. Thakor, Andrew Winterbottom
- Правопреемник/учебное заведение: Dept. of Radiology, Addenbrookes Hospital, Univ. of Cambridge, Cambridge, UK
- Дата публикации документа: 2011-07-31
- Страна опубликовавшая документ: Великобритания
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://www.springerlink.com/content/h0747573177x61x5/
- Вложения: Нет
- Аналитик: Helix
Objectives
With increasing experience, endovascular aortic aneurysm repair (EVAR) has been extended to patients with less suitable aorto-iliac anatomy in an attempt to reduce peri-operative mortality. However, more complex EVAR procedures may take longer and can result in higher rates of complications, additional interventional procedures and more frequent radiological imaging, which may offset some of the benefit. This study determined the radiation burden for standard EVAR, as determined by the EVAR-1 trial criteria, and more complex EVAR.
Methods
A total of 123 elective patients aged >60, with aneurysms >5.5 cm who received a bifurcated stent-graft were allocated into a group based on whether or not they fulfilled strict EVAR-1 trial criteria. The mean radiation dose was calculated for each group, together with the additional radiation burden from routine pre- and post-EVAR CT examinations and pre-EVAR iliac artery embolisation.
Results
Patients not meeting the EVAR-1 trial criteria had significantly longer fluoroscopic screening times and higher radiation doses. The radiation burden in all patients was higher following exposure from routine CT examinations and following pre-EVAR iliac artery embolisation.
Conclusion
Whilst the radiation from standard EVAR is acceptable, more complicated and challenging EVARs, accompanied with additional radiological investigations and procedures, can significantly increase the radiation burden.
Категория: Ищем научные статьи | Нет комментариев »
Комментарии
Статистика
Категорий: 179
Статей всего: 2,003
По типу:
Видео: 36
Выдержка с форума: 1
Контактные данные: 12
Научная статья: 1388
Не заполнено: 5
Новостная статья: 317
Обзор технологии: 42
Патент: 219
Тех.подробности: 34
Тип: 1
Комментариев: 6,627
Изображений: 3,005
Подробней...
ТОР 10 аналитиков
-
Глаголева Елена - 591
Дмитрий Соловьев - 459
Helix - 218
Ридна Украина))) - 85
Наталья Черкасова - 81
max-orduan - 29
Елена Токай - 15
Роман Михайлов - 9
Мансур Жигануров - 4
Дуванова Татьяна - 3
Календарь
Авторизация
Ошибка в тексте?
Выдели её мышкой!
И нажми Ctrl+Enter