A 10-DEGREE OF FREEDOM EXOSKELETON REHABILITATION ROBOT WITH ERGONOMIC SHOULDER ACTUATION MECHANISM
- Тип контента: Научная статья
- Номер документа: 3418
- Название документа: A 10-DEGREE OF FREEDOM EXOSKELETON REHABILITATION ROBOT WITH ERGONOMIC SHOULDER ACTUATION MECHANISM
- Номер (DOI, IBSN, Патент): 10.1142/S0219843611002344
- Изобретатель/автор: Xiong Caihua, Xaolin Huang, Wenbin Chen, Sun Ronglei
- Правопреемник/учебное заведение: State Key Lab of Digital Manufacturing Equipment and Technology, Institute of Rehabilitation and Medical Robotics, Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan, China
- Дата публикации документа: 2011-03-01
- Страна опубликовавшая документ: Сингапур
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://www.worldscinet.com/ijhr/08/0801/S0219843611002344.ht
- Вложения: Нет
- Аналитик: Helix
Due to the advantages of more intensiveness, long duration, repeatability, and task-orientation, robot-assistant training has become a promising technology in stroke rehabilitation. Regarding the upper extremity, the natural coordination called shoulder rhythm is the most challenge to the design of ergonomic shoulder exoskeleton. Based on kinematic analysis of movement of shoulder complex, a 10-degree-of-freedom (DoF) exoskeleton rehabilitation robot with six-DoF shoulder actuation mechanism driven by pneumatic muscle through Bowden cable transmitting force is proposed. The kinematic relationship between shoulder girdle motion and the humerus flexion/retroflexion and abduction/adduction was described. The compact mechanisms for cable tension and cable disconnect/connect respectively were proposed to realize the cable automatic tension and drive-unit/manipulating-unit detachment. In order to verify the manipulability of the proposed robot during assisting patient with performing activities of daily living (ADLs), the performance criteria, i.e., normalized dexterity measure and manipulability ellipsoid, are used to evaluate and compare with human upper extremity. The evaluated results confirm the ergonomic design of shoulder mechanism of the rehabilitation robot that can provide approximate dexterity of human upper extremity in ADLs.
Категория: Ищем научные статьи | Нет комментариев »
Комментарии
Статистика
Категорий: 179
Статей всего: 2,003
По типу:
Видео: 36
Выдержка с форума: 1
Контактные данные: 12
Научная статья: 1388
Не заполнено: 5
Новостная статья: 317
Обзор технологии: 42
Патент: 219
Тех.подробности: 34
Тип: 1
Комментариев: 6,627
Изображений: 3,005
Подробней...
ТОР 10 аналитиков
-
Глаголева Елена - 591
Дмитрий Соловьев - 459
Helix - 218
Ридна Украина))) - 85
Наталья Черкасова - 81
max-orduan - 29
Елена Токай - 15
Роман Михайлов - 9
Мансур Жигануров - 4
Дуванова Татьяна - 3
Календарь
Авторизация
Ошибка в тексте?
Выдели её мышкой!
И нажми Ctrl+Enter