http://myexs.ru/wp-content/themes/multiflex-4-10/img/header.gif
http://myexs.ru/wp-content/themes/multiflex-4-10/img/bg30.jpg

Short-term locomotor adaptation to a robotic ankle exoskeleton does not alter soleus Hoffmann reflex amplitude

Дата: Июль 31st, 2010 Автор:
+ Показать свойства документа
  • Тип контента: Научная статья
  • Номер документа: 6375
  • Название документа: Short-term locomotor adaptation to a robotic ankle exoskeleton does not alter soleus Hoffmann reflex amplitude
  • Номер (DOI, IBSN, Патент): Не заполнено
  • Изобретатель/автор: Pei-Chun Kao, Daniel P Ferris, Cara L Lewis
  • Правопреемник/учебное заведение: Не заполнено
  • Дата публикации документа: 2010-07-31
  • Страна опубликовавшая документ: Не заполнено
  • Язык документа: Английский
  • Наименование изделия: Не заполнено
  • Источник: Journal of NeuroEngineering and Rehabilitation
  • Вложения: Да
  • Аналитик: Глаголева Елена

Background: To improve design of robotic lower limb exoskeletons for gait rehabilitation, it is critical to identify neural mecha-nisms that govern locomotor adaptation to robotic assistance. Previously, we demonstrated soleus muscle recruitment decreased by ~35% when walking with a pneumatically-powered ankle exoskeleton providing plantar flexor torque under soleus proportional myoelec-tric control. Since a substantial portion of soleus activation during walking results from the stretch reflex, increased reflex in-hibition is one potential mechanism for reducing soleus recruitment when walking with exoskeleton assistance. This is clinically re-levant because many neurologically impaired populations have hyperactive stretch reflexes and training to reduce the reflexes could lead to substantial improvements in their motor ability. The purpose of this study was to quantify soleus Hoffmann (H-) reflex res-ponses during powered versus unpowered walking. Methods: We tested soleus H-reflex responses in neurologically intact subjects (n=8) that had trained walking with the soleus controlled robotic ankle exoskeleton. Soleus H-reflex was tested at the mid and late stance while subjects walked with the exoskeleton on the treadmill at 1.25 m/s, first without power (first unpowered), then with power (powered), and finally without power again (second unpowered). We also collected joint kinematics and electromyography. Re-sults: When the robotic plantar flexor torque was provided, subjects walked with lower soleus electromyographic (EMG) activation (27-48%) and had concomitant reductions in H-reflex amplitude (12-24%) compared to the first unpowered condition. The H-reflex am-plitude in proportion to the background soleus EMG during powered walking was not significantly different from the two unpowered conditions. Conclusion: These findings suggest that the nervous system does not inhibit the soleus H-reflex in response to short-term adaption to exoskeleton assistance. Future studies should determine if the findings also apply to longterm adaption to the exo-skeleton.

Категория: Научные статьи | Нет комментариев »

Комментарии

Добавить комментарий

Ваш e-mail не будет опубликован. Обязательные поля помечены *


Статистика

Категорий: 179
Статей всего: 2,003
По типу:
 Видео: 36
 Выдержка с форума: 1
 Контактные данные: 12
 Научная статья: 1388
 Не заполнено: 5
 Новостная статья: 317
 Обзор технологии: 42
 Патент: 219
 Тех.подробности: 34
 Тип: 1
Комментариев: 6,710
Изображений: 3,005
Подробней...

ТОР 10 аналитиков

    Глаголева Елена - 591
    Дмитрий Соловьев - 459
    Helix - 218
    Ридна Украина))) - 85
    Наталья Черкасова - 81
    max-orduan - 29
    Елена Токай - 15
    Роман Михайлов - 9
    Мансур Жигануров - 4
    Дуванова Татьяна - 3

Календарь

  • Июль 2010
    Пн Вт Ср Чт Пт Сб Вс
    « Июн   Авг »
     1234
    567891011
    12131415161718
    19202122232425
    262728293031  
  • Авторизация

    Ошибка в тексте?

    Выдели её мышкой!

    И нажми Ctrl+Enter