Archive for Май 8th, 2006
Harness Design and Coupling Stiffness for Two-Axis Torso Haptics
- Тип контента: Научная статья
- Номер документа: 1714
- Название документа: Harness Design and Coupling Stiffness for Two-Axis Torso Haptics
- Номер (DOI, IBSN, Патент): 10.1109/HAPTIC.2006.1627067
- Изобретатель/автор: Hollerbacht, J.M., Grow, D.I.
- Правопреемник/учебное заведение: University of Utah, Department of Mechanical Engineering, e-mail: david.grow@utah.edu
- Дата публикации документа: 2006-05-08
- Страна опубликовавшая документ: США
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Да
- Аналитик: Дмитрий Соловьев
This paper describes a harness design for transmitting both horizontal and vertical forces to the torso of a user on a locomotion interfaces. For horizontal forces, an exoskeleton-like mechanism distributes forces between the shoulders and hips and accommodates to the complicated motions of the back and shoulders relative to hips. For vertical forces, a body weight support harness is integrated into the exoskeleton-like mechanism. A passive elastic element has been devised that ensures consistent strap tightening. Measurements are presented that shows the stiffness of the mechanical coupling of harness to subject for the purposes of faithful force application to the torso.
Категория: Научные статьи | Нет комментариев »
Performance Enhancement of a Haptic Arm Exoskeleton
- Тип контента: Научная статья
- Номер документа: 904
- Название документа: Performance Enhancement of a Haptic Arm Exoskeleton
- Номер (DOI, IBSN, Патент): 10.1109/HAPTIC.2006.1627127
- Изобретатель/автор: Sledd, A., O'Malley, M.K.
- Правопреемник/учебное заведение: Mechanical Engineering and Materials Science, Rice University, Houston, TX USA 77005, amsledd@rice.edu
- Дата публикации документа: 2006-05-08
- Страна опубликовавшая документ: США
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Да
- Аналитик: Дмитрий Соловьев
A high-quality haptic interface is typically characterized by low apparent inertia and damping, high structural stiffness, minimal backlash, and absence of mechanical singularities in the workspace. In addition to these specifications, exoskeleton haptic interface design involves consideration of space and weight limitations, workspace requirements, and the kinematic constraints placed on the device by the human arm. In this paper, the authors present the redesign of an existing five degree-of-freedom haptic arm exoskeleton. The redesign efforts focus primarily on ensuring smooth operation of the exoskeleton’s moving parts to minimize backlash, reducing cost and build time by simplifying the design, and increasing the torque output while continuing to use electric actuators for ease of control. The accompanying computer control system was developed in parallel with the mechanical redesign effort. The newly redesigned exoskeleton presented is capable of providing kinesthetic feedback to the joints of the lower arm and wrist of the operator, and will be used in future work for robot-assisted rehabilitation and training.
Категория: Научные статьи | Нет комментариев »
Development of NTU wearable exoskeleton system for assistive technologies
- Тип контента: Научная статья
- Номер документа: 687
- Название документа: Development of NTU wearable exoskeleton system for assistive technologies
- Номер (DOI, IBSN, Патент): 10.1109/ICMA.2005.1626705
- Изобретатель/автор: Xiaopeng Liu, Low, K.H., Haoyong Yu
- Правопреемник/учебное заведение: Sch. of Mech. & Aerosp. Eng., Nanyang Technol. Univ., Singapore, Singapore
- Дата публикации документа: 2006-05-08
- Страна опубликовавшая документ: Сингапур
- Язык документа: Английский
- Наименование изделия: Не заполнено
- Источник: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&a
- Вложения: Да
- Аналитик: Дмитрий Соловьев
This paper presents a wearable lower extremity exoskeleton (LEE) developed as a platform for research works on enhancement and assistive the ability of human’s walking and load carrying. The whole process of the first prototype design is introduced together with the sub-systems, inner/outer exoskeleton, the attached flexible waist and footpad with sensors. Simulation model and feedback control with the ZMP method were established using Adams and Matlab. The ultimate goal of the current research work is to design and control a power assisted system, which integrates human’s intellect as the control system for manipulating the wearable power-aided device. The feasibility and initial performance of the designed system are also discussed.
Категория: Научные статьи | Нет комментариев »
Статистика
Категорий: 179
Статей всего: 2,003
По типу:
Видео: 36
Выдержка с форума: 1
Контактные данные: 12
Научная статья: 1388
Не заполнено: 5
Новостная статья: 317
Обзор технологии: 42
Патент: 219
Тех.подробности: 34
Тип: 1
Комментариев: 6,672
Изображений: 3,005
Подробней...
ТОР 10 аналитиков
-
Глаголева Елена - 591
Дмитрий Соловьев - 459
Helix - 218
Ридна Украина))) - 85
Наталья Черкасова - 81
max-orduan - 29
Елена Токай - 15
Роман Михайлов - 9
Мансур Жигануров - 4
Дуванова Татьяна - 3
Календарь
Авторизация
Ошибка в тексте?
Выдели её мышкой!
И нажми Ctrl+Enter